(4)
Lunkenheimer Non-Return Valves cut out a boiler automatically when inside pressure drops suddenly or when heat is withdrawn. External spring is reversed and valve acts as a spring-loaded stop-chock valve. Spring may be adjusted from the outside while valve is under pressure to compensate for excessive steam pulsations. Valves may be installed in either vertical or horizontal position.
Bodies and Bonnets Cast Iron. ASTM A-126 Trim Seat, disc, back seat bushing and yoke bushing is S1 steam bronze, ASTM B-61.
Seating SurfacesRegrindable. Seat disc and all other parts renewable. Installation Note Connection should be made directly to boiler outlet nozzle. Intervening pipe ...
(4)
Lunkenheimer Non-Return Valves cut out a boiler automatically when inside pressure drops suddenly or when heat is withdrawn. External spring is reversed and valve acts as a spring-loaded stop-check valve. Spring may be adjusted from the outside while valve is under pressure to compensate for excessive steam pulsations. Valves may be installed in either vertical or horizontal position.
Bodies and Bonnets A2I6 WCB, Cast Steel
Trim A216 WCB. 410 St. St.
Seating Surfaces A216 WCB 13CR with facing
Installation Note Connection should be made directly to boiler outlet nozzle. Intervening pipe should be kept as short as possible. Normally shipped with external ...